For non-magnetic beryllium-copper tools, see also ATEX-tools
2018-12 EMAREI Katalog Titanwerkzeug Auszug Englisch Deutsch (pdf)
Herunterladen2022-05-25 Price List EMAREI Titanium Tools (pdf)
Herunterladen2022-05 Emarei MRI Tool Sets (pdf)
HerunterladenE2I0500ST Emarei MRI Tool Set Stainless Steel A2 (pdf)
HerunterladenEAI0500TT Emarei MRI Tool Set Titanium Dedicated for Siemens MRI and Philips MRI (pdf)
HerunterladenEAI0501TT (ATC) Emarei MRI Tool Set Titanium Dedicated for GE MRI (pdf)
HerunterladenEAI0501TT Emarei MRI Tool Set Titanium Dedicated for GE MRI (pdf)
HerunterladenIt is said, that the first impression counts when it comes to the judgement of a company or a person. This is the reason, why many companies choose EMAREI ® Safety Tool Cases. They know that they are judged by the radiologists and all people around them and the better the impression and services conducted, the higher the probability that the business and personal relationship will last for a very long time. The judgement does not only apply to the person itself who is judged, it applies also the equipment which is carried by the service technician and brought into the customer´s premises. Especially when it comes to service aspects, all people working in the environment of strong magnets and especially MRI´s as well as explosive zones should live up to its role model and should only bring tested and correctly marked products to the customer.
If you or your company are interested to get an individually compiled tool set with your company logo and all relevant safety marks and certificates, please do not hesitate to send us your RfQ to info@ingdaum.com with a list of those non-magnetic tools which should be in the tool case and you will receive a detailed quotation DAP your business location within 24 hours.
EMAREI® Tool Tests, Titanium, Stainless Steel and Beryllium Copper Tools Test conducted on August 7, 2016 and in August 2019 at University of Southern California Hospital, Los Angeles, CA with a 3-Tesla MR system (General Electric Healthcare, Milwaukee, WI)
Non-clinical testing demonstrated that the DOUBLE OPEN-END WRENCH, 30/32-mm, Titanium and Beryllium Copper is MR Conditional and can be used in the MRI environment according to the following conditions:
IMPORTANT NOTE: This product is intended for use inside of the magnetic resonance imaging (MRI) environment (e.g., in the MR system room). However, it is not intended for use directly inside of the MR system (e.g., inside of the bore of the scanner), during the operation of the scanner (i.e., during an MRI procedure). As such, the assessment of MRI issues for this product entailed an assessment of translational attraction in relation to exposure to a 3-Tesla MR system, only.
NOTE: The above information applies to all tools made from the same material that are smaller in size/dimensions.